1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(3): 324-327, 2023 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-37288638

RESUMO

On October 21, 2021, the National Medical Products Administration issued and implemented the Self-examination Management Regulations for Medical Device Registration. The regulations clarify the specific requirements of the registration applicants in the process of self-examination, and put forward detailed requirements from the aspects of self-examination ability, self-examination report, declaration materials and responsibility requirements, so as to ensure the orderly development of the self-examination of medical device registration. Based on the actual verification work of in vitro diagnostic reagent, this study briefly discussed the understanding of the relevant contents of the regulations, aiming to provide some reference for enterprises and related supervision departments that have the requirement of registered self-examination.


Assuntos
Legislação de Dispositivos Médicos , Kit de Reagentes para Diagnóstico , Kit de Reagentes para Diagnóstico/normas
2.
Clin Chem Lab Med ; 61(4): 608-626, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36716120

RESUMO

The EU In-Vitro Diagnostic Device Regulation (IVDR) aims for transparent risk-and purpose-based validation of diagnostic devices, traceability of results to uniquely identified devices, and post-market surveillance. The IVDR regulates design, manufacture and putting into use of devices, but not medical services using these devices. In the absence of suitable commercial devices, the laboratory can resort to laboratory-developed tests (LDT) for in-house use. Documentary obligations (IVDR Art 5.5), the performance and safety specifications of ANNEX I, and development and manufacture under an ISO 15189-equivalent quality system apply. LDTs serve specific clinical needs, often for low volume niche applications, or correspond to the translational phase of new tests and treatments, often extremely relevant for patient care. As some commercial tests may disappear with the IVDR roll-out, many will require urgent LDT replacement. The workload will also depend on which modifications to commercial tests turns them into an LDT, and on how national legislators and competent authorities (CA) will handle new competences and responsibilities. We discuss appropriate interpretation of ISO 15189 to cover IVDR requirements. Selected cases illustrate LDT implementation covering medical needs with commensurate management of risk emanating from intended use and/or design of devices. Unintended collateral damage of the IVDR comprises loss of non-profitable niche applications, increases of costs and wasted resources, and migration of innovative research to more cost-efficient environments. Taking into account local specifics, the legislative framework should reduce the burden on and associated opportunity costs for the health care system, by making diligent use of existing frameworks.


Assuntos
Serviços de Laboratório Clínico , Kit de Reagentes para Diagnóstico , Humanos , Kit de Reagentes para Diagnóstico/normas , União Europeia , Serviços de Laboratório Clínico/legislação & jurisprudência
3.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-982238

RESUMO

On October 21, 2021, the National Medical Products Administration issued and implemented the Self-examination Management Regulations for Medical Device Registration. The regulations clarify the specific requirements of the registration applicants in the process of self-examination, and put forward detailed requirements from the aspects of self-examination ability, self-examination report, declaration materials and responsibility requirements, so as to ensure the orderly development of the self-examination of medical device registration. Based on the actual verification work of in vitro diagnostic reagent, this study briefly discussed the understanding of the relevant contents of the regulations, aiming to provide some reference for enterprises and related supervision departments that have the requirement of registered self-examination.


Assuntos
Legislação de Dispositivos Médicos , Kit de Reagentes para Diagnóstico/normas
4.
Indian J Pathol Microbiol ; 65(1): 105-110, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35074973

RESUMO

INTRODUCTION: Optimal DNA and RNA quantity and purity is essential for downstream molecular biology experimentation and to avoid re-processing of sample. Despite availability of different kits and automated systems for nucleic acid isolation there is limited data on their performance evaluation, more so with pediatric blood samples, that are usually compromised in quantity. Hence, we evaluated the performance of automated QIAcube platform using pediatric blood samples in parallel with manual Qiagen extraction kits. MATERIALS AND METHODS: : A total of 500 samples were analyzed based on groups of PBMC and direct blood input. The isolated DNA and RNA were surveyed for quantity and quality tests by spectrophotometric and downstream analysis. RESULTS: : There was no significant difference in the DNA quantity (ng/ul) between manual and automated method based on similar sample input but quality (260/280) was significantly better with the QIAcube platform when direct blood and or PBMCs were used for extraction respectively (1.82 ± 004 Vs. 1.84.002; P-0.000008 and 1.859 ± 005 Vs. 1.843 ± 0.003; P-0.02). Moreover, the standard error mean was low for both quantity and quality in the QIAcube method suggesting uniformity. Comparison of quality assessment by spectrophotometer and qubit fluorimeter showed that QIAcube sheared DNA less (P- 0.038) as compared to manual method (P-0.013). Also, time taken to process the samples in QIAcube was 23% less than the kit-based method. CONCLUSION: Overall analysis of QIAcube platform suggests that it yields more better, uniform, and less-sheared quality of nucleic acid in a relatively less time as compared to manual extraction kits.


Assuntos
Automação Laboratorial/normas , Células Sanguíneas , DNA/isolamento & purificação , Leucócitos Mononucleares , Biologia Molecular/métodos , RNA/isolamento & purificação , Kit de Reagentes para Diagnóstico/normas , Automação Laboratorial/métodos , Criança , Pré-Escolar , DNA/normas , Humanos , Lactente , Biologia Molecular/instrumentação , Biologia Molecular/normas , RNA/normas
5.
PLoS One ; 17(1): e0262733, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35061822

RESUMO

This study aims at establishing specimens pooling approach for the detection of SARS-CoV-2 using the RT-PCR BGI and Sansure-Biotech kits used in Gabon. To validate this approach, 14 positive samples, stored at -20°C for three to five weeks were analyzed individually (as gold standard) and in pools of five, eight and ten in the same plate. We created 14 pools of 5, 8 and 10 samples using 40 µL from each of the selected positive samples mixed with 4, 7 and 9 confirmed negative counterparts in a total volume of 200 µL, 320 µL and 400 µL for the pools of 5, 8 and 10 respectively. Both individual and pooled samples testing was conducted according to the BGI and Sansure-Biotech RT-PCR protocols used at the Professor Daniel Gahouma Laboratory (PDGL). Furthermore, the pooling method was also tested by comparing results of 470 unselected samples tested in 94 pools and individually. Results of our experiment showed that using a BGI single positive sample with cycle threshold (Ct) value of 28.42, confirmed by individual testing, detection occurred in all the pools. On the contrary samples with Ct >31 were not detected in pools of 10 and for these samples (Ct value as high as 37.17) their detection was possible in pool of 8. Regarding the Sansure-Biotech kit, positive samples were detected in all the pool sizes tested, irrespective of their Ct values. The specificity of the pooling method was 100% for the BGI and Sansure-Biotech RT-PCR assays. The present study found an increase in the Ct values with pool size for the BGI and Sansure-Biotech assays. This trend was statistically significant (Pearson's r = 0.978; p = 0,022) using the BGI method where the mean Ct values were 24.04±1.1, 26.74±1.3, 27.91±1.1 and 28.32±1.1 for the individual, pool of 5, 8 and 10 respectively. The testing of the 470 samples showed that one of the 94 pools had a positive test similar to the individual test using the BGI and Sansure-Biotech kits. The saving of time and economizing test reagents by using the pooling method were demonstrated in this study. Ultimately, the pooling method could be used for the diagnosis of SARS-CoV-2 without modifying the accuracy of results in Gabon. We recommend a maximum pool size of 8 for the BGI kit. For the Sansure-Biotech kit, a maximum pool size of 10 can be used without affecting its accuracy compared to the individual testing.


Assuntos
Teste de Ácido Nucleico para COVID-19/normas , COVID-19/diagnóstico , RNA Viral/genética , SARS-CoV-2/genética , Manejo de Espécimes/métodos , COVID-19/epidemiologia , Gabão/epidemiologia , Serviços de Saúde , Humanos , Kit de Reagentes para Diagnóstico/normas , SARS-CoV-2/classificação , Sensibilidade e Especificidade
6.
Anal Bioanal Chem ; 414(5): 1773-1785, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34958396

RESUMO

Nucleic acid tests to detect the SARS-CoV-2 virus have been performed worldwide since the beginning of the COVID-19 pandemic. For the quality assessment of testing laboratories and the performance evaluation of molecular diagnosis products, reference materials (RMs) are required. In this work, we report the production of a lentiviral SARS-CoV-2 RM containing approximately 12 kilobases of its genome including common diagnostics targets such as RdRp, N, E, and S genes. The RM was measured with multiple assays using two different digital PCR platforms. To measure the homogeneity and stability of the lentiviral SARS-CoV-2 RM, reverse transcription droplet digital PCR (RT-ddPCR) was used with in-house duplex assays. The copy number concentration of each target gene in the extracted RNA solution was then converted to that of the RM solution. Their copy number values are measured to be from 1.5 × 105 to 2.0 × 105 copies/mL. The RM has a between-bottle homogeneity of 4.80-8.23% and is stable at 4 °C for 1 week and at -70 °C for 6 months. The lentiviral SARS-CoV-2 RM closely mimics real samples that undergo identical pre-analytical processes for SARS-CoV-2 molecular testing. By offering accurate reference values for the absolute copy number of viral target genes, the developed RM can be used to improve the reliability of SARS-CoV-2 molecular testing.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Genoma Viral , RNA Viral/genética , Kit de Reagentes para Diagnóstico/normas , SARS-CoV-2/genética , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/normas , Proteínas do Envelope de Coronavírus/genética , Proteínas do Envelope de Coronavírus/metabolismo , Proteínas do Nucleocapsídeo de Coronavírus/genética , Proteínas do Nucleocapsídeo de Coronavírus/metabolismo , RNA-Polimerase RNA-Dependente de Coronavírus/genética , RNA-Polimerase RNA-Dependente de Coronavírus/metabolismo , Dosagem de Genes , Expressão Gênica , Humanos , Células Jurkat , Lentivirus/genética , Lentivirus/metabolismo , Fosfoproteínas/genética , Fosfoproteínas/metabolismo , RNA Viral/metabolismo , RNA Viral/normas , Kit de Reagentes para Diagnóstico/provisão & distribuição , Padrões de Referência , Reprodutibilidade dos Testes , Glicoproteína da Espícula de Coronavírus/genética , Glicoproteína da Espícula de Coronavírus/metabolismo , Empacotamento do Genoma Viral
7.
Exp Clin Endocrinol Diabetes ; 130(2): 110-114, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33065741

RESUMO

OBJECTIVE: Glypican4 is an interesting new adipokine, which seems to play an important role in developmental processes and is potentially associated with metabolic changes in obesity and type 2 diabetes mellitus. Currently, only a few studies examined glypican4 in human blood, mainly in adults. DESIGN, PATIENTS AND MEASUREMENTS: The aim of our study was to investigate glypican4 serum levels in lean, overweight, and obese children and adolescents, to unravel a possible association between glypican4 serum levels and parameters of obesity and insulin resistance. In order to determine a suitable method for investigating glypican4 serum levels, we validated two commercially available human glypican4 ELISA kits, using serum and plasma samples of an obese, insulin-resistant patient, and a healthy control subject, a human recombinant glypican4 protein fragment and glypican4-overexpressing cell lysate. RESULTS: Using ELISA kit #1 we were not able to detect values above background level, apart from standard curve values. ELISA kit #2 initially seemed suitable to measure glypican4, but further validation experiments showed non-linearity of serial dilutions, no recognition of a human recombinant glypican4 protein fragment and non-linearity in the recovery of glypican4-overexpressing cell lysate. In addition, there was a considerable decrease (approx. 68%) of measured values between two experiments, performed at different time points with aliquots of the same serum sample. Contrary to that, further experiments found sample stability not to be compromised. CONCLUSIONS: Extensive evaluation of the performance of two commercially available ELISA kits led to the conclusion that none of them is applicable for the measurement of glypican4 in human blood samples.


Assuntos
Diabetes Mellitus/sangue , Ensaio de Imunoadsorção Enzimática , Glipicanas/sangue , Resistência à Insulina , Obesidade Pediátrica/sangue , Kit de Reagentes para Diagnóstico/normas , Adolescente , Criança , Humanos , Resistência à Insulina/fisiologia , Reprodutibilidade dos Testes
8.
J Med Virol ; 94(2): 582-586, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-31021428

RESUMO

OBJECTIVE: Approximately 1 million adenovirus immunochromatography (IC) kits are annually used in Japan. However, no practical strategies have been developed regarding their use for detecting adenovirus. The present study aims to verify the usefulness of clinical manifestations in making decisions regarding the use of adenovirus IC kits for children with upper respiratory infections (URI). METHODS: The medical records of 825 pediatric cases tested by IC kits for adenovirus were extracted from clinical laboratory department database over a 3-year period at our hospital. Among them, 585 patients were suspected adenovirus URI, and their clinical manifestations were reviewed. After data cleaning, 10 types of clinical manifestations were statistically analyzed between adenovirus IC kit-positive and -negative groups. Multivariate analysis was performed to select significant clinical manifestations using adenovirus IC kit positivity as the objective variable. RESULTS: Among 585 pediatric patients, the cases of 420 patients, with suitable data for whom no other pathogen was detected, were reviewed. Adenovirus was detected in 86 cases. Multivariate analysis identified a significant difference for three clinical manifestations: (1) fever ≥ 39.0°C, (2) rhinorrhea, and (3) tonsillar exudate. The negativity rate for the IC kit was 90% when none of the three manifestations was observed. CONCLUSIONS: The results suggested that IC kits for adenovirus tend to give negative results in cases that lack all the three above mentioned clinical manifestations.


Assuntos
Infecções por Adenovirus Humanos/diagnóstico , Adenovírus Humanos/isolamento & purificação , Cromatografia de Afinidade/normas , Kit de Reagentes para Diagnóstico/normas , Infecções Respiratórias/virologia , Infecções por Adenovirus Humanos/virologia , Criança , Pré-Escolar , Cromatografia de Afinidade/métodos , Bases de Dados Factuais , Feminino , Febre/etiologia , Humanos , Limite de Detecção , Modelos Logísticos , Masculino , Análise Multivariada , Infecções Respiratórias/complicações , Estudos Retrospectivos , Rinorreia/etiologia
9.
Lancet Infect Dis ; 22(1): 85-96, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34499863

RESUMO

BACKGROUND: Treatment of latent tuberculosis infection is an important strategy to prevent tuberculosis disease. In the USA, three tests are used to identify latent tuberculosis infection: the tuberculin skin test (TST) and two IFN-γ release assays (T-SPOT.TB and QuantiFERON). To our knowledge, few large studies have compared all three tests among people at high risk of latent tuberculosis infection or progression to tuberculosis disease. We aimed to assess test agreement between IFN-γ release assays and TST to provide guidance on their use in important risk groups. METHODS: In this observational cohort study, we enrolled participants at high risk of latent tuberculosis infection or progression to tuberculosis disease at ten US sites with 18 affiliated clinics, including close contacts of infectious tuberculosis cases, people born in countries whose populations in the USA have high (≥100 cases per 100 000 people) or moderate (10-99 cases per 100 000 people) tuberculosis incidence, and people with HIV. Participants were interviewed about demographics and medical risk factors, and all three tests were administered to each participant. The primary endpoints for this study were the proportions of positive test results by test type stratified by risk group and test concordance by risk group for participants with valid results for all three test types. The study is registered at ClinicalTrials.gov, NCT01622140. FINDINGS: Between July 12, 2012, and May 5, 2017, 26 292 people were approached and 22 131 (84·2%) were enrolled in the study. Data from 21 846 (98·7%) participants were available for analysis, including 3790 (17·3%) born in the USA and 18 023 (82·5%) born outside the USA. Among non-US-born participants overall, the RR comparing the proportions of TST-positive results (7476 [43·2%] of 17 306 participants) to QuantiFERON-positive results (4732 [26·5%] of 17 882 participants) was 1·6 (95% CI 1·6-1·7). The risk ratio (RR) for the comparison with the proportion of T-SPOT.TB-positive results (3693 [21·6%] of 17 118 participants) was 2·0 (95% CI 1·9-2·1). US-born participants had less variation in the proportions of positive results across all tests. The RRs for the proportion of TST-positive results (391 [10·9%] of 3575 participants) compared with the proportion of QuantiFERON-positive results (445 [12·0%] of 3693 participants) and T-SPOT.TB-positive results (295 [8·1%] of 3638 participants) were 0·9 (95% CI 0·8-1·0) and 1·3 (1·2-1·6), respectively. 20 149 (91·0%) of 21 846 participants had results for all three tests, including 16 712 (76%) non-US-born participants. Discordance between TST and IFN-γ release assay results varied by age among non-US-born participants and was greatest among the 848 non-US-born children younger than 5 years. 204 (87·2%) of 234 non-US-born children younger than 5 years with at least one positive test were TST-positive and IFN-γ release assay-negative. The proportion of non-US-born participants who were TST-negative but IFN-γ release assay-positive ranged from one (0·5%) of 199 children younger than 2 years to 86 (14·5%) of 594 participants aged 65 years and older (ptrend<0·0001). Test agreement was higher between the two IFN-γ release assays than between TST and either IFN-γ release assay, regardless of birthplace. κ agreement was particularly low between TST and IFN-γ release assays in non-US-born children younger than 5 years. INTERPRETATION: Our findings support the preferential use of IFN-γ release assays for the diagnosis of latent tuberculosis in high-risk populations, especially in very young and older people born outside the USA. FUNDING: US Centers for Disease Control and Prevention.


Assuntos
Testes de Liberação de Interferon-gama/normas , Tuberculose Latente/diagnóstico , Tuberculose Latente/epidemiologia , Kit de Reagentes para Diagnóstico/normas , Teste Tuberculínico/normas , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Lactente , Tuberculose Latente/microbiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Inquéritos e Questionários , Estados Unidos/epidemiologia , Adulto Jovem
10.
J Infect Dev Ctries ; 15(11): 1701-1707, 2021 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-34898499

RESUMO

INTRODUCTION: Most hospitals rely on rapid antigen-detection kits for the diagnosis of rotavirus infection. Several small studies reviewed the sensitivity and specificity of some of these kits. These studies showed discrepancy in results obtained for sensitivity and specificity that varied according to the type of kit used, area of study, and type of test used as standard for diagnosis of rotavirus infection. The objective of the study is to determine the sensitivity and specificity of five commonly used rotavirus immunoassay kits in comparison to RT-PCR as standard. METHODOLOGY: Stool samples (N = 1,414) collected from children under 5 years of age hospitalized with gastroenteritis were tested for rotavirus by immunoassay kits and RT-PCR in a prospective hospital-based surveillance study conducted at 7 centers in Lebanon. Concordance and discrepancy between the two methods was used to calculate sensitivity and specificity, using RT-PCR as the "gold standard". RESULTS: The sensitivity and specificity were respectively 95.08% and 86.62% for the SD Bioline® (Standard Diagnostics, Inc, South Korea) kit calculated on 645 samples, 65.86% and 45.90% for the VIROTECT® (Trinity Biotech, Ireland) kit calculated on 327 samples, 83.9% and 64.2% for the Rota-Strip (C-1001) (Coris Bioconcept, Belgium) calculated on 95 samples, 52.3% and 10.9% for the Acon® (Acon Laboratories, Inc, California, USA) kit calculated on 122 samples, 68.1% and 20% for the VIKIA® Rota-Adéno (Biomerieux, France) kit calculated on 32 samples. CONCLUSION: A wide discrepancy was detected between the calculated and advertised sensitivity and specificity for most of the kits.


Assuntos
Gastroenterite/diagnóstico , Imunoensaio/normas , Kit de Reagentes para Diagnóstico/normas , Infecções por Rotavirus/diagnóstico , Pré-Escolar , Fezes/virologia , Gastroenterite/virologia , Humanos , Lactente , Estudos Prospectivos , Kit de Reagentes para Diagnóstico/virologia , Reação em Cadeia da Polimerase em Tempo Real , Rotavirus , Sensibilidade e Especificidade
11.
Am J Trop Med Hyg ; 106(2): 543-549, 2021 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-34844208

RESUMO

Typhoid is an endemic in Fiji with increases observed since the early 2000s and frequent outbreaks reported. We assessed the diagnostic accuracy of currently available typhoid rapid diagnostic tests (RDTs) (TUBEX, Typhidot Rapid, and Test-It assay) to establish their performance against blood culture in Fiji and to examine their suitability for rapid typhoid outbreak identification. The performance of RDTs was assessed in the public health reference laboratory in Suva, Fiji, according to the manufacturers' instructions. A simulation was used to examine the potential use of RDTs for attribution of a febrile illness outbreak to typhoid. For the diagnostic evaluation, 179 patients were included; 49 had blood culture-confirmed typhoid, 76 had fever as a result of non-typhoid etiologies, and 54 were age-matched community controls. The median (interquartile range) age was 29 (20-46) years. Of the participants, 92 (51.4%) were male and 131 (73.2%) were indigenous Fijians. The sensitivities of the tests were 77.6% for TUBEX, 75.5% for Typhidot Rapid, and 57.1% for Test-It assay. The Test-It assay had the highest specificity of 93.4%, followed by Typhidot Rapid 85.5% and TUBEX 60.5%. Typhidot Rapid had the best performance in the simulation for attribution of a febrile illness outbreak to typhoid. Typhoid RDTs performed suboptimally for individual patient diagnosis due to low sensitivity and variable specificity. We demonstrate that RDTs could be useful in the field for rapid attribution of febrile illness outbreaks to typhoid. Typhidot Rapid had the best combination of sensitivity, specificity, positive and negative predictive values, cost, and ease of use for this purpose.


Assuntos
Anticorpos Antibacterianos/sangue , Testes Diagnósticos de Rotina/normas , Surtos de Doenças , Febre Tifoide/diagnóstico , Febre Tifoide/epidemiologia , Adolescente , Adulto , Hemocultura , Estudos de Casos e Controles , Feminino , Fiji/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Kit de Reagentes para Diagnóstico/normas , Estudos Retrospectivos , Salmonella typhi , Sensibilidade e Especificidade , Febre Tifoide/microbiologia
12.
J Acquir Immune Defic Syndr ; 88(2): 220-227, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34506362

RESUMO

BACKGROUND: The genetic divergence of HIV-1 group O is high relative to pandemic group M, which could impact detection and quantification of plasma RNA. Recent commercial kits for RNA quantification seem to show good performances in HIV-1/O, but discrepancies are still observed. Here, we compare the performances of 3 commercial assays for the RNA quantification of HIV-1/O. METHODS: We studied the RNA quantification of 117 clinical samples using Abbott RealTime HIV-1, Cepheid Xpert HIV-1 Viral Load, or Roche Cobas TaqMan HIV-1 v2. First, we conducted a qualitative description, and second, we focused on a quantitative analysis of the results above 40 cp/mL. The degree of agreement between methods and the strength of the correlation of viral load determination were estimated using Bland-Altman plot and Passing-Bablok regression with the Spearman coefficient, respectively. RESULTS: Our 2-by-2 analysis showed that the Abbott and Cepheid assays were very close in terms of correlation and dispersion of points, whereas Roche presented higher values in the highest range of quantification (>5 log10). The Cepheid assay combined better correlation with the consensus value and a lower dispersion of values, leading to an overall better performance of quantification. The quantification was still impacted by intragroup genetic diversity with, here, 1 strain (YBF26). CONCLUSIONS: Using a new approach to compare the performances of RNA quantification between more than 2 techniques, we demonstrated that Cepheid could be the most suitable assay for HIV-1/O quantification, although the results from all assays remained strain dependent.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/genética , RNA Viral/genética , Kit de Reagentes para Diagnóstico/normas , Soropositividade para HIV , HIV-1/isolamento & purificação , Humanos , Reação em Cadeia da Polimerase em Tempo Real , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral
13.
Viruses ; 13(9)2021 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-34578299

RESUMO

Phleboviruses (genus Phlebovirus, family Phenuiviridae) are emerging pathogens of humans and animals. Sand-fly-transmitted phleboviruses are found in Europe, Africa, the Middle East, and the Americas, and are responsible for febrile illness and nervous system infections in humans. Rio Grande virus (RGV) is the only reported phlebovirus in the United States. Isolated in Texas from southern plains woodrats, RGV is not known to be pathogenic to humans or domestic animals, but serologic evidence suggests that sheep (Ovis aries) and horses (Equus caballus) in this region have been infected. Rift Valley fever virus (RVFV), a phlebovirus of Africa, is an important pathogen of wild and domestic ruminants, and can also infect humans with the potential to cause severe disease. The introduction of RVFV into North America could greatly impact U.S. livestock and human health, and the development of vaccines and countermeasures is a focus of both the CDC and USDA. We investigated the potential for serologic reagents used in RVFV diagnostic assays to also detect cells infected with RGV. Western blots and immunocytochemistry assays were used to compare the antibody detection of RGV, RVFV, and two other New World phlebovirus, Punta Toro virus (South and Central America) and Anhanga virus (Brazil). Antigenic cross-reactions were found using published RVFV diagnostic reagents. These findings will help to inform test interpretation to avoid false positive RVFV diagnoses that could lead to public health concerns and economically costly agriculture regulatory responses, including quarantine and trade restrictions.


Assuntos
Reações Cruzadas/imunologia , Phlebovirus/imunologia , Kit de Reagentes para Diagnóstico/normas , Vírus da Febre do Vale do Rift/imunologia , Testes Sorológicos/normas , Animais , Infecções por Bunyaviridae/classificação , Infecções por Bunyaviridae/diagnóstico , Infecções por Bunyaviridae/imunologia , Cavalos/virologia , Phlebovirus/classificação , Phlebovirus/patogenicidade , Febre do Vale de Rift/diagnóstico , Febre do Vale de Rift/imunologia , Vírus da Febre do Vale do Rift/patogenicidade , Testes Sorológicos/métodos , Ovinos/virologia , Estados Unidos
14.
J Med Virol ; 93(11): 6309-6316, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34375007

RESUMO

Serological tests detecting antibodies for Epstein-Barr virus (EBV) antigens are frequently used to define infection status. Several new automated assays are available for this purpose. We compared the performance of Architect, Immulite, Vidas, and Euroimmune immunofluorescence assays (IFA)/enzyme-linked immunosorbent assays (ELISA) for the detection of EBV viral capsid antigen (VCA) immunoglobulin M (IgM), VCA IgG, Epstein-Barr nuclear antigen (EBNA)-1 IgG. The routine diagnosis of EBV in our laboratory is done by anti-EBV VCA IgM IFT, anti-EBV VCA IgG IFT, and anti-EBNA-1 IgG ELISA (Euroimmune) Kits. Samples were tested with EBV Kits of Architect, Immulite, and Vidas for anti-VCA IgM, anti-VCA IgG, and anti-EBNA-1 IgG. The agreement between assays was calculated for each marker individually and for the determination of the EBV infection profile, based on the combination of three markers. BIOCHIP Sequence EBV (Avidity test) and/or EUROLINE EBV Profile 2 (IgG/IgM) were used as confirmatory assays to resolve discrepancies. The best concordance for VCA IgM detection was between Immulite and Vidas; for VCA IgG and EBNA-1 IgG were between Architect and Vidas. The sensitivities and specificities for VCA IgM were 97% and 88% for IFA, 100% and 94% for Architect, 100% and 99% for Vidas, and 100% and 100% for Immulite, respectively. The most problematic marker was EBNA-1 IgG with a 68.1% specificity by Immulite. Vidas panel had a perfect performance (100%) for determining all EBV profiles. Overall, evaluated assays had comparable performance. There were more discordant VCA IgG and EBNA-1 IgG results than VCA IgM results. The agreement between Architect and Vidas was better than other assays.


Assuntos
Anticorpos Antivirais/sangue , Infecções por Vírus Epstein-Barr/sangue , Infecções por Vírus Epstein-Barr/diagnóstico , Herpesvirus Humano 4/imunologia , Kit de Reagentes para Diagnóstico/normas , Testes Sorológicos/normas , Adolescente , Adulto , Antígenos Virais/imunologia , Proteínas do Capsídeo/imunologia , Criança , Pré-Escolar , Infecções por Vírus Epstein-Barr/imunologia , Feminino , Humanos , Imunoglobulina M/sangue , Lactente , Medições Luminescentes/instrumentação , Medições Luminescentes/normas , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Testes Sorológicos/instrumentação , Testes Sorológicos/métodos , Adulto Jovem
15.
Sci Rep ; 11(1): 17148, 2021 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-34433845

RESUMO

The low biomass of respiratory samples makes it difficult to accurately characterise the microbial community composition. PCR conditions and contaminating microbial DNA can alter the biological profile. The objective of this study was to benchmark the currently available laboratory protocols to accurately analyse the microbial community of low biomass samples. To study the effect of PCR conditions on the microbial community profile, we amplified the 16S rRNA gene of respiratory samples using various bacterial loads and different number of PCR cycles. Libraries were purified by gel electrophoresis or AMPure XP and sequenced by V2 or V3 MiSeq reagent kits by Illumina sequencing. The positive control was diluted in different solvents. PCR conditions had no significant influence on the microbial community profile of low biomass samples. Purification methods and MiSeq reagent kits provided nearly similar microbiota profiles (paired Bray-Curtis dissimilarity median: 0.03 and 0.05, respectively). While profiles of positive controls were significantly influenced by the type of dilution solvent, the theoretical profile of the Zymo mock was most accurately analysed when the Zymo mock was diluted in elution buffer (difference compared to the theoretical Zymo mock: 21.6% for elution buffer, 29.2% for Milli-Q, and 79.6% for DNA/RNA shield). Microbiota profiles of DNA blanks formed a distinct cluster compared to low biomass samples, demonstrating that low biomass samples can accurately be distinguished from DNA blanks. In summary, to accurately characterise the microbial community composition we recommend 1. amplification of the obtained microbial DNA with 30 PCR cycles, 2. purifying amplicon pools by two consecutive AMPure XP steps and 3. sequence the pooled amplicons by V3 MiSeq reagent kit. The benchmarked standardized laboratory workflow presented here ensures comparability of results within and between low biomass microbiome studies.


Assuntos
Benchmarking/métodos , Microbiota , Kit de Reagentes para Diagnóstico/normas , Mucosa Respiratória/microbiologia , Biomassa , Humanos , Metagenômica/métodos , Metagenômica/normas , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/normas , RNA Ribossômico 16S/genética , Saliva/microbiologia
16.
BMC Microbiol ; 21(1): 236, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-34445973

RESUMO

BACKGROUND: The ePlex® and QIAstat-Dx® respiratory pathogen panels detect multiple respiratory pathogens, mainly viruses but also Legionella pneumophila, Mycoplasma pneumoniae and Bordetella pertussis. The assays have been marketed for use in nasopharyngeal swab specimens. For diagnosing bacterial pneumonia, lower respiratory tract (LRT) specimens are indicated. Aim of this study was to evaluate the performance of these syndromic panels for these three bacterial targets in samples from the LRT. Fifty-six specimens were collected from our repositories, five negative samples and fifty-one samples which had been previously tested positive with the routine diagnostic real-time PCR assays for Legionella spp. (N = 20), Bordetella spp. (N = 16) or M. pneumoniae (N = 15). RESULTS: The QIAstat-Dx Respiratory Panel V2 (RP) assay detected all of the L. pneumophila and B. pertussis positive samples but only 11/15 (73.3 %) of the M. pneumoniae targets. The ePlex Respiratory Pathogen Panel (RPP) assay detected 10/14 (71.4 %) of the L. pneumophila targets, 8/12 (66.7 %) of the B. pertussis positive samples and 13/15 (86.7 %) of the M. pneumoniae targets. CONCLUSIONS: No false-positive results were reported for all three bacterial pathogens by both assays. The clinical performance of both assays depended highly on the bacterial load in the sample and the type of specimen under investigation.


Assuntos
Bactérias/genética , Técnicas de Diagnóstico Molecular/normas , Kit de Reagentes para Diagnóstico/normas , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/microbiologia , Bactérias/classificação , Bactérias/isolamento & purificação , Bactérias/patogenicidade , Carga Bacteriana/métodos , Carga Bacteriana/normas , Feminino , Humanos , Masculino , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase Multiplex/instrumentação , Reação em Cadeia da Polimerase Multiplex/normas , Pneumonia Bacteriana/diagnóstico , Pneumonia Bacteriana/microbiologia
17.
J Med Virol ; 93(11): 6404-6407, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34347299

RESUMO

Heterophile antibody assays have been used to aid the diagnosis of infectious mononucleosis caused by the Epstein-Barr virus. Seven commercially available assays currently widely utilized in clinical laboratories were compared in this study. Variable performance characteristics and assay times are observed, and these pieces of data may assist clinical laboratories in assay selection and result interpretation.


Assuntos
Anticorpos Heterófilos/sangue , Anticorpos Antivirais/sangue , Técnicas de Laboratório Clínico/normas , Infecções por Vírus Epstein-Barr/diagnóstico , Mononucleose Infecciosa/diagnóstico , Mononucleose Infecciosa/imunologia , Kit de Reagentes para Diagnóstico/normas , Adolescente , Anticorpos Heterófilos/imunologia , Criança , Técnicas de Laboratório Clínico/métodos , Infecções por Vírus Epstein-Barr/sangue , Humanos , Imunoglobulina M/sangue , Mononucleose Infecciosa/sangue , Adulto Jovem
18.
Clin Biochem ; 97: 62-66, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34343576

RESUMO

OBJECTIVE: Reagent lot-to-lot comparisons are recommended by accreditation bodies to ensure that the performance of each reagent lot meets acceptable standards for quality patient results. The general approach is comprised of performing quality control (QC) and patient comparison between the old and new reagent lots and evaluating against a pre-defined criteria. Reagent lot comparison practices are often variable despite using the same instrument across different laboratories. This is costly, time consuming, and can lead to variability in acceptance criteria. While Clinical & Laboratory Standards Institute (CLSI) has a recommended guideline for reagent lot validation, it is often difficult to execute for small and rural laboratories due to limited resources. Defining the analytes required for detailed validation is important to allocate appropriate resources to ensure quality patient results. The goal of this study was to develop a standardized approach to reagent lot validation and optimize lab resources on Vitros chemistry instruments. DESIGN AND METHOD: This study consists of a retrospective and prospective analysis of reagent lot changes in dry slide chemistry analyzers (Ortho Clinical Diagnostics Vitros). Two years of retrospective reagent lot comparison data was obtained at a single site. A prospective study was conducted by assessing aliquots of 10 patient sample pools at 9 sites with Vitros analyzers. RESULTS: Of the 19 chemistry analytes evaluated, albumin, sodium, and total protein showed significant differences between reagent lots and also exceeded the pre-defined acceptance criteria. CONCLUSION: For these analytes, our recommendations are to perform a comprehensive lot validation with QC and patient samples. A simple lot validation with a reflex approach comprised of initially assaying QC can be adapted for the more stable analytes to allow achieving quality patient result in a resource constraint rural environment.


Assuntos
Química Clínica/instrumentação , Química Clínica/normas , Kit de Reagentes para Diagnóstico/normas , Equipamentos e Provisões , Humanos , Estudos Prospectivos , Controle de Qualidade , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
Diagn Microbiol Infect Dis ; 101(3): 115467, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34391073

RESUMO

The increased coverage of antiretroviral therapy has resulted in a decrease in the positive predictive value (PPV) and diagnostic sensitivity of early infant diagnosis assays. To evaluate the diagnostic performance of the Aptima HIV-1 Quant DX assay (Aptima) in detecting HIV infection at birth. The study was a cross-sectional laboratory based evaluation using whole blood DBS specimens. Samples were collected from HIV-exposed neonates at birth at two paediatric facilities in Gauteng between 1st March 2018 - 31st January 2020. Performance of the Aptima compared to the Cobas® AmpliPrep/Cobas® TaqMan HIV-1 Qualitative Test v2.0 was calculated using a two-by-two table and reported as proportions with 95% confidence intervals. A total of 363 infants met the inclusion criteria of which 4 (1.1%) had an Aptima result discordant with CAP/CTM HIV status: two (50%) negative and two (50%) positive. The Aptima assay had a sensitivity of 93.75% (95% CI: 79.19%-99.23%), specificity of 99.4% (95% CI: 97.83%-99.93%), PPV of 93.75% (95% CI: 78.98%-98.36%), negative predictive value of 99.4% (95% CI: 97.73%-99.84%), and overall accuracy of 98.9% (95% CI: 97.2%-99.7%). The Aptima yielded an error code on 37 (10.19%) results, of which 35 (94.59%) were resolved on repeat testing. Of the 32 HIV-detected specimens, 20 had a plasma VL result available (18 on Abbott and 2 on Cobas). The absolute median difference was 0.66 log10 (IQR: 0.36-1.71). The Aptima demonstrated good EID performance and can be considered as a qualitative EID assay.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/genética , Técnicas de Diagnóstico Molecular/normas , Triagem Neonatal/métodos , Kit de Reagentes para Diagnóstico/normas , Carga Viral/normas , Estudos Transversais , Infecções por HIV/sangue , Humanos , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/sangue , Sensibilidade e Especificidade , África do Sul , Carga Viral/métodos